色欲综合视频天天天综合网站

  • <td id="1wehn"><ruby id="1wehn"></ruby></td>
      1. TS - HCM01 Intelligent digital display temperature and humidity controller Temperature and humidity control panel module
        TS - HCM01 Intelligent digital display temperature and humidity controller Temperature and humidity control panel module
        TS - HCM01 Intelligent digital display temperature and humidity controller Temperature and humidity control panel module
        TS - HCM01 Intelligent digital display temperature and humidity controller Temperature and humidity control panel module
        TS - HCM01 Intelligent digital display temperature and humidity controller Temperature and humidity control panel module
        TS - HCM01 Intelligent digital display temperature and humidity controller Temperature and humidity control panel module
        TS - HCM01 Intelligent digital display temperature and humidity controller Temperature and humidity control panel module

        TS - HCM01 Intelligent digital display temperature and humidity controller Temperature and humidity control panel module

        Model NO.
        HCM01
        Price:
        USD 1.00-10.00 / pieces
        Minimum order quantity:
        10 pieces
        Supply Ability:
        50000 pieces / Week
        Country of Origin:
        shenzhen
        Quantity:
        • Place of Origin:US;14882
        • Type:Intelligent digital display temperature and humidity controller
        • D/C:16
        • Package:Temperature and humidity control panel module
        • Model Number:HCM01
        • Brand Name:2018+

        Product electrical characteristics

        Humidity measurement range:0%RH~99.9%RH

        Temperature measurement range:-40℃~80

        Resolving power:?Humidity 0.1%RH,?Temperature 0.1

        Measurement accuracy:±3%RH0.5%

        Control accuracy:?0.1%RH;±0.1%

        Refresh rate:1S

        Input voltage:DC or AC 7V~24V

        Measurement input: AM2301 temperature and humidity integrated sensor

        Output: two way 10A relay

        Environmental requirements:-10℃--60,?humidity 20%--85%

        ?

        Specification size:

        Overall power consumption:?Quiescent current≤20ma,?Pull current≤50ma.04.jpg05.jpg

        Picture?2 for?Boot display alarm settings interface

        ?

        Instructions:

        Fnction:

        1. 1.?With temperature and humidity control function.
        2. 2.?Can display the current temperature and humidity in real time.
        3. 3.?With over limit alarm function.
        4. 4.?Relay working indication function.
        5. 5.?Switching display function with degrees Celsius and Fahrenheit.

        Indicator light:

        1. 1.?The middle of the indicator light for the power indicator,The indicator light is turn on when the right power is on.
        2. 2.?D9 is a humidity indicator relay indicator lamp, Equipment began to work when the D9 light is turn on.
        3. 3.?D8 is the temperature relay indicator lamp, Equipment began to work when the D8?light is turn on.
        4. 4.?D4 is an indicator of degrees Fahrenheit and Celsius,?It means that the temperature is Fahrenheit when the light is turn

        on. It means that the temperature is degrees centigrade when the lamp is off.

        1. 5.?D3 is the normal working status indicator light?,?It flashes about once every 1.8 seconds?when reading the temperature

        and humidity.

        ?

        Key note:

        Look at the picture 1, Buttons from left to right respectively?SET,+ and - .

        ?

        Function description:

        1. 1.?High temperature start - cooling mode:

        Refrigeration equipment?begins to?work?when the starting temperature value is greater than the stop temperature

        value and the temperature?measurement is greater than or equal to the beginning temperature.?Refrigeration equipment will stop working?when the temperature?measurement?is less than or equal to the stop temperature.

        ???For example,?Set the starting temperature to 20,?Stop temperature is 15,?D8 light is turn on and refrigeration equipment work when the detection temperature is greater than or equal to 20℃.?D8 light?went off and refrigeration equipment will stop working?when the temperature value is less than 15.

        1. 2.?Low temperature start - heating mode:
        2. ?

        Heating equipment begins to work?when the starting temperature value is less than the stop temperature value and

        the temperature is less than or equal to the beginning temperature.?Heating equipment will stop working?when the test temperature is greater than or equal to the stop temperature.

        For example,?Set the starting temperature to 15,Stop temperature is 20℃.?D8 lights is turn on?and Heating

        equipment begins to work?when the temperature measurement?value is less than or equal to 15℃.D8?light?went off and Heating equipment to stop working?when the temperature measurement?value is greater than or equal to the stop temperature.

        1. 3.?High humidity start - Desiccant mode:

        The system automatically determines the mode of the dehumidification?when the startting humidity value is higher

        than the value of the stop humidity.In this mode,?dehumidification?equipment to start work?when humidity detection is greater than or equal to the beginning of humidity.?Dehumidification?equipment?will stop working?when the humidity

        detection is less than or equal to the stop humidity.

        For example,?Set the starting humidity to 60%RH,?Stop humidity is 40%RH.?Indicator light D9 lamp is turn on?and dehumidification?equipment?start to work?when the detected humidity value greater than or equal to 60%RH.?Indicator light D9 went off and dehumidification?equipment?to stop working?when Humidity detection value is less than or equal to 40%RH.

        1. 4.?Low humidity start?-?humidification mode

        ???The system automatically enters the humidification mode?when theset start humidity is less than the value of the humidity value.?In this mode,?Humidification equipment began to work?when thehumidity detection is less than or equal to the beginning of humidity.Humidification equipment will stop working?when thehumidity detection is Greater than or equal to the beginning of humidity.

        For example,?Set the starting humidity to 40%RH,?Stop humidity is 60%RH, Indicator light D9is turn on and?humidification equipment into the work?when thehumidity detection value is less than or equal to 40%RH.?Indicator light D9went off and humidification equipment?to stop working?thehumidity detection value is?greater than or equal to 60%RH.

        1. 5.?Temperature correction mode

        The temperature of the system setting can be corrected is±30.?Temperature can be corrected?when the

        Temperature?measurement is not accurate?and there's a higher level thermometer.?Under normal condition shows the temperature is the actual measured temperatureA?plus correction temperature B.

        For example,Correction temperature Bis?-0.5,?The actual measured temperature ais25,?The temperature?display in digital tube is 24.5.

        1. 6.?Humidity correction mode

        System set humidity correction is ±10%RH,?Humidity calibration can be carried out?when measuring humidity is not

        accurate and there is a higher level of humidity. Normal display of the humidity is the actual measurement of the humidity A plus the correction of humidity B.

        For example,?Corrected humidity B is-0.5%RH,?The actual measured humidity A is 25.0%RH,?The humidity?display in digital tube is24.5%RH.

        1. 7.?Temperature alarm mode:

        Display showing Axx (default is A00) and flashing in the boot 3 seconds,You can use"+"and"-"to set the alarm

        Mode,?Alarm modes are defined as follows:

        A00: alarm function off (default)

        A01: the currently detection of humidity beyond the starting temperature or stop temperature of 1,buzzer alarm.

        A02: the currently detection of humidity beyond the starting temperature or stop temperature of2,buzzer alarm.

        A03: the currently detection of humidity beyond the starting temperature or stop temperature of3,buzzer alarm.

        and so on,?max can be setA30.

        For example,Set alarm modeA03,?Starting temperatureis20,Stop temperature?is?30,Buzzer sound alarmwhen the measured temperature is above 33℃?or below 17℃.

        ?

        Concrete setting method:

        Notes:?The following settings are automatically saved to EEPROM

        1. 1.?Set start temperature:

        ????Long press S button for 3 seconds,?Measured temperature digital display P01?andthe start temperature of the current setting.?Press + and - button to adjust this value,Long press is continuous adjustment.Long press S button to exit the adjustment?after the adjustment is completed?or automatic exit without key action in 10S.

        1. 2.?Set the stop temperature:

        Long press S button for 3 seconds, Measured temperature digital display P01?and short press SET button once again?

        to adjust P01 into P02.?At this point, the"measured humidity"shows the current setting of the stop temperature value.?Press + and - button to adjust this value,?Long press is continuous adjustment.?Long press S button to exit the adjustment?after the adjustment is completed?or automatic exit without key action in 10S.

        1. 3.?Set the correct temperature:

        Long press S button for 3 seconds, Measured temperature digital display P01?and short press SET button two times?

        to adjust P01 into P03.?At this time,"measured humidity"display the current settings of the correct temperature?value.Press + and - button to adjust this value,?Long press is continuous adjustment.?Long press S button to exit the adjustment?after the adjustment is completed?or automatic exit without key action in 10S.

        1. 4.?Set up the humidity:

        ???Long press S button for 3 seconds, Measured temperature digital display P01?and press SET button again?to adjust P01 into P04.At this time, the"measured humidity"shows the present setting of the starting humidity value.?Press + and - button to adjust this value,?Long press is continuous adjustment.?Long press S button to exit the adjustment?after the adjustment is completed?or automatic exit without key action in 10S.

        1. 5.?Set the stop humidity:

        Long press S button for 3 seconds, Measured temperature digital display P01?and short press SET button again?to

        adjust P01 into P05.?At this time, the"measured humidity"shows the present setting of the stop humidity value.Press + and - button to adjust this value,?Long press is continuous adjustment.?Long press S button to exit the adjustment?after the adjustment is completed?or automatic exit without key action in 10S.

        1. 6.?Set the correct humidity:

        Long press S button for 3 seconds, Measured temperature digital display P01?and short press SET button again?to

        adjust P01 into P06.?At this time,"measured humidity"display the present set of the correction of the humidity value.?Press + and - button to adjust this value,?Long press is continuous adjustment.?Long press S button to exit the adjustment?after the adjustment is completed?or automatic exit without key action in 10S.

        1. 7.?Set alarm mode:

        See also"function description"7.temperature alarm mode.

        1. 8.?Restore the factory settings:

        Hold + and - press the button and then boot,?Display screen display"rrrr",?All settings are restored to factory

        settings after Buzzer sound three?times.

        1. 9.?Degrees Celsius and Fahrenheit switching

        Long press S button for 3 seconds, Measured temperature digital display P01?and short press SET button again?to

        adjust P01 into P07.?At this time,"measured humidity"display the present temperature model?(CCC?isdegrees Celsius,?FFF is Fahrenheit) ,press + and - button to switch the temperature display mode.All parameters will be automatically converted after the switch is completed. Long press S button to exit the adjustment?after the adjustment is completed?orautomatic exit without key action in 10S.

        ???

        Attach?form:

        ??

        ?Display the meaning of the character in the setting:

        Symbol

        significance

        Degrees Celsius?Range

        Degrees Fahrenheit?Range

        Factory Default

        P01

        Start temperature set symbol

        -40~80

        -40~176

        20.0

        P02

        Stop temperature set symbol

        -40~80

        -40~176

        30.0

        P03

        Set symbol for temperature correction value

        -8~8

        -14~14

        0.0

        P04

        Start up humidity set symbol

        0~99.9

        0-99.9

        40.0

        P05

        Stop humidity set symbol

        0~99.9

        0-99.9

        60.0

        P06

        Humidity correction value set symbol

        -30~30

        -30~30

        0.0

        P07

        Degrees Celsius and Fahrenheit switching

        CCC

        FFF

        CCC

        ?

        ?

        Send Message

        *
        * clear input
        go top Top
        Scan the QR code Close
        qr code
        qrcode

        Send Message

        *
        * clear input
        Choose language  
        色欲综合视频天天天综合网站